Be2works 452 Full New May 2026

The previous 452 models ran on Intel Atom or Celeron processors. The be2works 452 Full New debuts with a 12th Gen Intel Core i7 (Alder Lake P) or comparable AMD Ryzen Embedded processor. This results in:

| Feature | Previous Gen | be2works 452 Full New | | :--- | :--- | :--- | | Fieldbus | POWERLINK, Profinet RT | adds EtherCAT Master, Profinet IRT, and TSN | | Wireless | None | Integrated WiFi 6E and Bluetooth 5.3 (for commissioning) | | USB | 2.0 | USB 3.2 Gen 2 (10 Gbps for data logging) | | DIO | Optional modules | 16 onboard configurable high-speed DIO (1 µs latency) |


Challenge: Mixed-case palletizing with real-time weight distribution calculation.
Solution: The "Full" unlimited task system calculates optimal stacking patterns while controlling up to 12 servo axes in real time. be2works 452 full new


With the built-in Historian and unlimited tags, a craft brewery replaced three separate devices (PLC, gateway, and data logger) with a single 452 Full New. The WebView HMI allows shift managers to check fermentation progress from an iPad on the plant floor.


Q: Can I run my old 452 project on the Full New without changes? A: Yes, with the Migration Toolkit. However, you may need to adjust any direct memory addressing if your old code used deprecated SFR (Special Function Register) addresses. The Toolkit will flag these. The previous 452 models ran on Intel Atom

Q: Does "Full New" support OPC DA? A: No. OPC DA (Classic) is deprecated. The device supports OPC UA FX (Field eXchange) and MQTT. Use a gateway if you have legacy OPC DA clients.

Q: How hot does the NPU get under full load? A: At 100% NPU utilization (5 TOPS) and 40°C ambient, the case temperature reaches 71°C—well within spec. An external heatsink is recommended for enclosed cabinets without airflow. With the built-in Historian and unlimited tags, a

Troubleshooting tip #1: If the WebView dashboard is slow, check the "GPU Rendering" setting in the HMI server. Disabling hardware acceleration for the NPU frees up resources for control tasks.

Troubleshooting tip #2: The "Full New" logs all dropped packets to the audit trail. If you see excessive drops on the TSN ports, verify that all switches in the path support 802.1Qbu.


The launch of the 452 Full New is not an endpoint but a foundation. be2works has hinted at the following updates arriving in Q1-Q3 2026:

Thus, investing in the 452 Full New today ensures you are on the leading edge of automation for the next 6-8 years.