Hys3c210-cs Power Supply Page

Do not assume the colors match ATX standards! Industrial PSUs often use custom wiring. However, the standard HYS3C210-CS usually follows this layout:

Pro tip: Before plugging in a motherboard, jumper PS-ON to Ground with a paperclip and measure the voltages with a multimeter.

| Terminal Block | Label | Function | |----------------|-------|----------| | AC Input (L, N, ⏚) | L | Live (Brown) | | | N | Neutral (Blue) | | | ⏚ | Earth/Ground (Green/Yellow) – must connect | | DC Output (+V, -V) | +V | Positive DC output | | | -V | Negative DC output (common ground) | | Optional | Adj. | Output voltage trim potentiometer | | Optional | DC OK | LED indicator (green = normal) | hys3c210-cs power supply


| Feature | Specification | | :--- | :--- | | Model | HYS3C210-CS | | Input Voltage | 100 - 240V AC (Universal) | | Frequency | 50/60Hz | | Efficiency | >88% (Typical load) | | Cooling | Forced Air (Auto-Speed Fan) | | Operating Temp | -10°C to +50°C | | Dimensions | Compact Standard Rack/Desktop Mount | | Safety Standards | CE, RoHS, FCC Compliant |

Routers, switches, and fiber-optic transceivers in remote cabinets or cellular base stations often operate from 48V or 24V. The wide input range of the HYS3C210-CS allows it to handle unstable grid conditions. Do not assume the colors match ATX standards

(Specifications are based on standard Hoymiles/Industry datasheets for the HYS3C210 series; slight variations may exist depending on firmware version).

Electrical Input:

  • Frequency: 50/60 Hz.
  • Measurement Capabilities:

    Communication Interface:

    Physical Characteristics:

    Go to top