For engineers evaluating Sucosoft-s30-s316, here are the critical technical details:
| Feature | Specification | | :--- | :--- | | Target Hardware | Lenze 3200 C (e.g., 3200 C, 3230 C, 3240 C) | | Supported Drive Series | Lenze 9300, 9400, i700, and 8400 (via system bus) | | Programming Languages | LD, FBD, ST, IL, SFC (IEC 61131-3) | | Motion Control | Up to 64 axes, 8 simultaneous interpolation channels (S316 only) | | Communication Protocols | CANopen (System Bus), CAN (Local Bus), Ethernet TCP/IP, PROFIBUS, EtherCAT (with gateway) | | Cycle Time | Down to 1 ms (position control loop), 250 µs (fast I/O) | | Runtime License | Requires hardware dongle (specific to S316 features) | | Operating System | Windows 7, 10 (32/64-bit), Windows 11 (compatibility mode) |
The Sucosoft‑S30‑S316 ecosystem represents a forgotten layer of industrial history—less glamorous than mainframes or early PCs, but equally foundational to late‑20th‑century automation.
Product Specification: Sucosoft-S30-S316
Introduction: The Sucosoft-S30-S316 is a high-performance, silicone-based softener designed to provide exceptional softening and finishing properties to various fabric types, especially focusing on S316 fabric specifications. This product aims to enhance fabric handle, improve drape, and provide a superior soft feel without compromising on fabric breathability or durability.
Key Features:
Technical Specifications:
Application Guidelines:
Benefits:
Storage and Safety Precautions:
Disclaimer: The information provided is based on our current knowledge and experience. The user is responsible for determining the suitability of our products for their particular use. We make no warranties, express or implied, as to the accuracy or completeness of the information provided.
This draft provides a general overview and technical details about the product. Specific parameters like concentration, application methods, and safety measures can be adjusted based on actual product characteristics and regulatory requirements.
Sucosoft S30-S316 is a legacy MS-DOS based programming software suite used for Klockner-Moeller (now Eaton) PS316 and PS306 series Programmable Logic Controllers (PLCs). It is largely considered obsolete in modern industrial environments but remains critical for maintaining or decommissioning legacy systems. ⚙️ Core Technical Specifications Target Hardware: Primarily designed for the (modular rack system) and Go to product viewer dialog for this item. (compact version).
Operating Environment: Runs on MS-DOS (version 3.3 or higher). Modern users typically require emulators like DOSBox or virtual machines running Windows 98/XP to execute it.
Programming Languages: Supports Ladder Diagram (LD), Instruction List (IL/IS), and Function Block Language (FBL). Sucosoft-s30-s316
Connectivity: Requires a specialized interface converter, such as the ZB4-501-UM1, to connect a PC's serial port to the PLC. ⚠️ Critical Limitations
No Source Code Upload: A major drawback is that you cannot retrieve the original source code directly from a
PLC. If you do not have the original offline project file, you can only download the compiled machine code, which is nearly impossible to edit.
Hardware Dependency: The software was originally distributed on 3.5" floppy disks. Finding official, uncorrupted copies today often requires sourcing from third-party surplus sites like eBay.
Modern Compatibility: Users frequently report "DATA TRANSFER ERROR" when using modern USB-to-Serial adapters. Standard settings are usually 9600 baud, 8 bits, no parity, and 1 stop bit.
Moeller Sucosoft S30 | Automation & Control Engineering Forum
Sucosoft S30-S316 is a legacy programming software suite. It was developed by Moeller (now Eaton).It is used to configure and program S30 series PLCs.Specifically, it targets the PS3 and PS316 controllers. 💻 Software Purpose Development: Create logic for modular PLC systems. Maintenance: Upload or download existing program files. Monitoring: Debug real-time data on the factory floor. Documentation: Print I/O lists and network diagrams. 🛠️ Key Technical Features
Programming Languages: Uses Instruction List (IL) and Ladder (LD).
Hardware Support: Primarily for the PS3-AC, PS3-DC, and PS316.
Interface: Requires a serial connection (RS232) for communication.
Operating System: Originally designed for MS-DOS environments. ⚠️ Modern Compatibility Issues OS Constraints: It does not run natively on Windows 10/11. Virtualization: Users often need DOSBox or a VM.
Hardware Cables: Modern PCs need a specialized USB-to-Serial converter. Legacy Status: This software is no longer actively updated. 🔌 Necessary Hardware Components PLC: A Moeller PS3 or PS316 unit. PC: A computer with a COM port or adapter. Cable: UM 1-1 or similar level-matching interface cable.
License: A valid authorization code for the S30-S316 package.
The Sucosoft S30-S316 is a specialized release agent manufactured by Klüber Lubrication, designed specifically for the food processing and packaging industries. It is a non-silicone, solvent-based fluid used to facilitate the easy removal of products from molds, conveyor belts, and processing machinery. Its primary distinguishing feature is its compliance with strict food safety regulations (NSF H1), making it suitable for use in environments where incidental contact with food products may occur. For engineers evaluating Sucosoft-s30-s316 , here are the
The Sucosoft S30-S316 represents the industry standard for facilities that require high-performance release properties without compromising food safety or downstream processability (painting/printing). Its non-silicone formulation offers a superior balance of release efficiency and surface quality, making it a critical consumable in modern food packaging and molding operations.
The Sucosoft S30-S316 is a legacy, DOS-based programming software package specifically designed for Klockner Moeller PS306 and PS316 Programmable Logic Controllers (PLCs). Essential Resources & Downloads
Software Files: You can find original installation files, such as koped6.exe, on the official Eaton Asset Server. User Manuals:
Installation & Programming: The DOK 9018-GB manual covers programming for PS306 and PS316 units.
Hardware Setup: For physical installation details, refer to the PS 316 Installation Instructions on ManualsLib. Critical Technical Tips
Hardware Interface: To connect your PC to the PLC, you typically need an interface converter like the ZB4-501-UM1 or an RS-232 connection.
OS Compatibility: Because it is DOS-based, you will likely need a virtual machine running Windows 98/XP or a DOS emulator to run it on modern hardware.
Online Connection Security: To monitor or edit a program online, the code on your PC must be byte-for-byte identical to the compiled code in the PLC. If they don't match, the software will only allow a raw data read (hex dump). Uploading Programs: Navigate to Online → Connect (or press F6).
Select the correct COM port and set the baud rate (default is often 9600).
Go to File → Upload from PLC to retrieve the compiled .prj or .spj file.
Are you trying to retrieve a program from an old machine, or are you looking to migrate this logic to a newer S40 system?
I’m unable to generate a full technical report on Sucosoft-s30-s316 because this appears to be a specific software or hardware identifier—likely related to Sucosoft S30 (a programming and visualization software for SAIA Burgess PLCs, now part of Honeywell). The s316 suffix might refer to a specific device profile, firmware version, or a customized variant.
To help you effectively, could you clarify:
Context of use:
If you can provide more details (or upload any error messages / file listings), I can produce a structured report with known data, or guide you on how to extract the needed information from Sucosoft S30 itself.
Sucosoft S30 is a legacy, DOS-based programming software for Klockner Moeller's PS316 and PS4-100 series PLCs. It is largely considered obsolete and is primarily used today for maintaining antiquated systems rather than new development. Key Features
Supported Languages: Allows programming in Instruction Set (IS), Ladder Diagram (LD), and Function Block Language (FBL).
Interactive Interface: Features a menu structure designed to guide programmers through main and sub-menus.
Multi-Function Keys: The software dynamically activates keys based on the selected operation to prevent input errors.
System Configuration: Includes a System Parameter Editor to set functions like program memory tests, cycle times, and password protection. Critical Limitations & "Pros and Cons"
Security Mechanisms: For an online connection, the program on the PC must be byte-for-byte identical to the machine code on the PLC. If they don't match exactly, the software will deny the connection.
Retrieval Challenges: There is no way to upload and retrieve original source code (ladder logic/comments) from a PS316; users can only get a compiled hex file.
Hardware Dependencies: Requires specific legacy hardware, such as an interface converter (ZB4-501-UM1) for communication.
Modern Compatibility: Because it is DOS-based, it is difficult to run on modern Windows operating systems without emulation. Verdict for Developers
Unless you are tasked with maintaining a legacy Moeller PS316 system, it is recommended to transition to Sucosoft S40. S40 is Windows-based and can directly convert older S30 programs.
Moeller Sucosoft S30 | Automation & Control Engineering Forum
If you're looking for an interesting essay on this topic, here’s a structured angle you could explore:
If you are new to the software, follow this workflow: Ladder Diagram (LD)
While classified as a food-safe lubricant, Sucosoft S30-S316 contains a solvent carrier (typically aliphatic hydrocarbons).