The Tempro Plus D 360 is equipped with the Wittmann R8.2 control system, featuring a resistive touchscreen and haptic emergency stop.
Main screen elements:
Menu structure:
CAUTION: Running the pump without water will destroy the mechanical seal within 30 seconds.
Initial fill:
Automatic water top-up: The D 360 features a built-in level probe. If water drops below minimum, the controller closes the heater, opens the fill valve, and displays “Refill water – check leakage.”
The manual is explicit: Use treated water. Hard water scaling is the #1 killer of D 360 heating elements. Wittmann Tempro Plus D 360 Manual
| Parameter | Value | |-----------|-------| | Temperature range | +20°C … +140°C (standard) / +160°C (optional) | | Heating capacity | 9 kW (3 x 3 kW stainless steel immersion heaters) | | Cooling type | Direct injection (water-to-water) | | Cooling water requirement | 10–40°C, 2–6 bar, flow rate ≥ 40 L/min | | Pump type | Centrifugal, stainless steel impeller | | Max. pump pressure | 4.8 bar at 0 L/min; 2.5 bar at 60 L/min | | Flow measurement | Turbine wheel sensor (4–20 mA output) | | Tank volume | 3.6 liters (stainless steel, insulated) | | Electrical supply | 400V ±10%, 3-phase, 50/60 Hz, 16 A (CEE plug) | | Control system | Wittmann R8.2 controller with 5.7” color touchscreen |
Short-term shutdown (less than 48 hours):
Press STOP. The pump continues for 3 minutes to cool the heaters, then turns off. Leave water inside to prevent seal drying. The Tempro Plus D 360 is equipped with the Wittmann R8
Long-term storage (over 1 week):